Core Facility - Services

The main task of the Sándor Damjanovich Cell Analyses Core Facility is maintaining the instruments of BSI and providing access for researchers. Another main goal of the Core Facility is to support high-quality scientific research, our colleagaues can undertake the assistance and implementation of a wide range of measurements in a service-oriented manner:

 

Zeiss LSM880 – Airy-scan confocal laser scanning microscope

  • co-localization analyses with 200 nm resolution
  • multichannel confocal imaging
  • dual channel fluorescent correlation and cross-correlation spectroscopy
  • optical sectioning, 3D reconstruction

 

OLYMPUS FluoView FV1000 confocal microscope

  • co-localization analyses with 200 nm resolution
  • multichannel confocal imaging
  • multichannel fluorescent correlation and cross-correlation spectroscopy
  • optical sectioning, 3D reconstruction
  • FRET, FRAP measurements

 

Nikon N-STORM Super-Resolution Inverted Microscope

  • confocal imaging
  • dSTORM, 3D STORM imaging, ~20 nm resolution
  • fixed and living cell samples with single molecule detection,
  • imaging with TIRF illumination
  • intracellular trafficking

 

PicoQuant - FLIM

  • multichannel fluorescence lifetime imaging
  • Förster resonance energy transfer (FRET)
  • multichannel fluorescence anisotropy imaging
  • multicolor fluorescence correlation spectroscopy (FCS, FCCS)
  • multichannel fluorescence imaging

 

LSC – iCys laser scanning cytometer

  • light scattering analyses
  • recording multiple parameters from a large number of cells
  • cellular morphology analyses
  • histological samples, adherent or interacting cells
  • multichannel fluorescence imaging

 

FLIM-TIRF Fluorescence Lifetime Imaging Microscope

  • multicolor fluorescence lifetime imaging with TIRF/wide field illumination
  • fluorescence lifetime determination
  • fast CCD imaging
  • multicolor fluorescence imaging with TIRF/wide field illumination
  • fixed and live cell samples with single molecule detection

 

Olympus - TIRF total internal reflection fluorescence

  • co-localization analyses with 200 nm resolution
  • fixed and living cell samples with single molecule detection
  • imaging with TIRF (total internal reflection fluorescence) illumination
  • multichannel fluorescent imaging
  • TIRF-FCS, 2D fluorescence correlation spectroscopy

 

Novocyte 3000 RYB flow cytometer

  • recording multiple fluorescence and light scattering parameters on a cell-by-cell basis
  • automated measurement of a large number of cells in microplates
  • Förster resonance energy transfer (FRET)
  • cell viability measurements
  • determination of cell surface protein expression level

 

Yobin Yvon Fluorolog spectrofluorometer

  • measurement of fluorescence excitation and emission spectra
  • fluorescence anisotropy
  • kinetic measurements
  • Förster resonance energy transfer (FRET)
  • 90 degree and front-face detection

 

Electrophysiology workstation

  • patch clamp measurements
  • determination of intracellular Ca2+ concentration
  • fast microscopic fluorimetry (~ms)
  • fluorescence microscopy
  • microinjection
  • ratiometric fluorescence measurements

 

    Frissítés dátuma: 2020.05.10.


    Tisztelt Felhasználó!

     

    A Debreceni Egyetem kiemelt fontosságúnak tartja a rendelkezésére bocsátott, illetve birtokába jutott személyes adatok védelmét. Ezúton tájékoztatjuk Önt, hogy a Debreceni Egyetem a 2018. május 25. napjától kötelezően alkalmazandó Általános Adatvédelmi Rendelet alapján felülvizsgálta folyamatait és beépítette a GDPR előírásait az adatkezelési és adatvédelmi tevékenységébe. A felhasználók személyes adatait a Debreceni Egyetem korábban is teljes körültekintéssel kezelte, megfelelve az érvényben lévő adatkezelési szabályozásoknak. A GDPR előírásait követve frissítettük Adatvédelmi Tájékoztatónkat, amelyet az alábbi linkre kattintva olvashat el: Adatkezelési tájékoztató. DE Kancellária VIR Központ